Endovascular access
Appearance
Choice of site
[edit | edit source]- Consider:
- Appropriateness for procedure - size, location
- Ability to obtain haemostasis afterwards - seal with manual compression/closure device
- Difficult factors: significant calcification; small diameter vessels
- Ability to safely convert to open if there is a complication
- Ensuring that cannulation of that site will have minimal adverse effects on the tissue being supplied by the access vessel
- Rarely an issue for diagnostic procedures
- Options:
- CFA most common, followed by brachial and radial artery (when a smaller-calibre device can be used and femoral access is disadvantageous)
- Popliteal and tibial can be used for lower extremity interventions, but rarely first choice, and not considered for diagnostic-only procedures
- Others: carotid, subclavian, axillary, iliac
Vessels:
[edit | edit source]- Axillary
- Easier to use brachial, since it's easier to access and there's minimal difference in calibre
- Technique
- Upper arm in abduction and flexion
- Locate intramuscular groove between triceps and coracobrachialis
- Haemostasis by compression against the humerus (bleeding can create a compartment syndrome for the median nerve)
- Iliac artery
- Open surgical approach is easiest
- Percutaneous techniques are contraindicated due to difficulty in establishing haemostasis
- CFA
- Can be compressed against femoral head
- Can be converted to an open approach easily with a groin cut-down
- Can accommodate devices as large as 26F and suture-based closure devices
- Anatomy:
- Continuation of EIA as it crosses under the inguinal ligament, giving off circumflex iliac and superficial epigastric branches
- 5-8cm long
- Bifurcates into SFA and PFA
- Medial to femoral nerve, lateral to CFV
- Overlies medial aspect of femoral head
- Antegrade access:
- Harder than retrograde, as you need to enter CFA above the bifurcation, which means a steep downward angle
- In obese patients, might need someone to retract the pannus
- Entering too close to the bifurcation means it will be difficult to selectively cannulate the SFA
- Retrograde access:
- Aim to obtain access over the femoral head, just above the femoral bifurcation but below the inguinal ligament with the needle pointing cranially
- Punctures cranial to the IL may be difficult to seal
- Punctures too distally increase risk AVF from PFA or plaque dissection of the proximal SFA
- Brachial artery
- Can be compressed against the humerus - can be challenging though
- 6F sheaths can be used safely in most patients
- Anatomy
- Palpable just over the olecranon process when the arm is supinated
- Use USS in combination with micropuncture technique
- Risk of median nerve compression with a haematoma
- Technique
- Need to delineate the bifurcation prior to attempting access, so that entry into the largest part of the vessel is achieved
- Popliteal artery
- USS very useful in differentiating from popliteal veins
- Haemostasis can be difficult, as effective compression in the fatty popliteal space is hard
- Anatomy:
- Continuation of the SFA as it exits Hunter's canal in the distal medial thigh
- Divides into ATA and TPT
- Flanked on each side by dupicated popliteal vein
- Can be accessed medially either above or below the knee, or posteriorly using a prone position
- Tibial arteries/peroneal arteries
- Commonly accessed using micropuncture technique assisted by USS
- Small sheaths and soft wires
- Anterior tibial artery
- Anatomy
- Anterior compartment of leg, dorsal surface of the foot (dorsalis pedis)
- Anatomy
- Posterior tibial artery
- Anatomy
- Palpable near the ankle, and amenable to access here as it is easily compressed
- Anatomy
- Peroneal artery
- Anatomy
- Deep posterior compartment of the leg
- Generally travels between tibia and fibula
- Hard to reach, rarely used
- Anatomy
- Radial artery
- Can accommodate sheaths between 4F and 6F
Adjuncts to obtain access
[edit | edit source]- Manual palpation of pulse
- Two fingers - one proximal and one distal, spread out by a few centimetres
- Access needle inserted directly between the two fingers
- Radiographic guidance
- Useful when a pulse is either absent, or not able to be appreciated due to overlying scarring
- USS guidance
Technique
[edit | edit source]- Needles
- Single-wall: almost universally used for percutaneous access. 18-gauge needle for 0.035-inch guide wire. 21 gauge needle for 0.018-inch guide wire.
- Double-wall: blunt-tipped hollow needle with an inner bevelled stylet. Historically used to puncture both anterior and posterior walls, then inner stylet removed, then needle slowly withdrawn until blood comes back.
- Micropuncture needle technique
- Vessel identified with USS
- 21-gauge needle inserted at 30-45 degrees, so it enters the vessel at site of visualisation
- 0.018-inch floppy tip guidewire inserted into the vessel
- Needle removed from over the wire
- 4F introducer sheath
- Inner canula of sheath removed, along the guidewire
- 0.035-inch wire can be inserted at this point and sheath upsized to 5F or 6F if needed for definitive access
- Standard needle technique (for easily palpable femoral pulses in otherwise uncomplicated anatomy)
- 18-gauge needle and 0.035-inch J-tip moveable core steel guidewire (don't use hydrophilic-coated guidewire for initial entry as the coating can shear off and embolise from the needle)
- Straight to 5F or 6F sheath
- This technique is helpful in situations where tracking the 4F sheath over the less supportive 0.018-inch wire can be hard, like in scarred groins or when accessing a Dacron graft
- Sheaths
- Inside calibre measured by French size, from 4F to 11F
- Have a haemostatic valve at the end
- Braided sheaths can be used when cannulating a vessel through dense tissue or making sharp turns that can lead to kinking of the sheath
- Most commonly 10cm length for diagnostic purposes, but available 5-100cm
- 45cm sheath typically used working on the contralateral iliac system or beyond, and a 90cm sheath used to work on the carotids. Chosen sheath should be no longer than necessary.
- Guidewires
- Jagwire (Boston Scientific) commonly used at Austin
- Nitinol with Endo-Glide coating
- 5cm hydrophilic tip
- 0.025 or 0.035-inch diameters
- 260 or 450cm length
- Straight or angled tip
- Good for use in biliary duct cannulation from top or bottom
- Jagwire (Boston Scientific) commonly used at Austin
- Catheters
- Vehicles used to deliver the radiographic contrast agent to the area of interest
- Most catheters 2F-6F
- 2F and 3F are microcatheters for delivery of embolisation coils
- Types of diagnostic catheters:
- Non-selective - used to inject a high volume of contrast into relatively large blood vessels, typically using power injection. Multiple side holes along the last 15mm to reduce the 'jet effect'.
- Selective - their shape facilitates engagement in the orifice of a branch vessel, for either direct injection or subsequent guidewire passage. Generally have an end hole only (no side-holes), and therefore can't inject with too much pressure. Divided into single-curved, double-curved and reverse-curved configurations.
- Single-curved: ideal for cannulating a side branch vessel coming off at less than 45-degree angle from the aorta.
- Double-curved: angle up to 90 degrees or greater.
- Reverse-curved: typically have a 180-degree curve, for vessels that come off steeply.
- Interventional catheters:
- Crossing
- Used for crossing occluded/stenotic vessels
- Guiding catheters - essentially sheaths with tips with different lengths and shapes to permit selective cannulation
- Crossing
- Closure devices
- Simple manual compression
- Not too tight - lead to thrombosis
- Hold for 5-20 minutes
- 6 hours mandated bedrest
- Closure devices
- Seal the access hole in some way or another
- Minimise need for compression and bed rest
- Increase risk of groin infection and leg ischaemia.
- Angio-Seal - intra-arterial absorbable anchor is placed against an externally placed collagen sponge, and these are sandwiched together. Good for arteries >5mm without significant calcification, and can be used to close sites up 8F. Can get ischaemic complications when deployed incorrectly.
- Mynx - polyethylene glycol polymer closes the tissue track over the puncture site, which dissolves within 30 days. Haemostasis for up to 6F. Higher risk of ischaemic and bleeding complications.
- ProGlide - single polypropylene stitch to suture close arteriotomy sites up to 6F. Can be used off-label to close large arteries by putting two of them together. Device failure - manual compression, additional ProGlide use, or open repair.
- Simple manual compression
Consent: bleeding, infection, thromboemboli, failure, additional procedures, contrast allergy or nephropathy, limb loss, anaesthetic, neurovascular
Complications
[edit | edit source]- Access site
- Risk factors
- Obesity
- Diseased access vessels
- Large sheath size
- Anticoagulation
- Bleeding (1%)
- Initial management:
- Apply pressure while the patient is stabilised (push against an anatomic structure)
- Reverse anticoagulation
- Reassess with imaging (?CTA or USS)
- Endovascular balloon control as an adjunctive technique while definitive management is obtained
- Definitive management:
- Continued bleeding may need open repair
- Endovascular treatment with peripheral endografting
- Initial management:
- Haematoma (3%)
- Initial management:
- Apply pressure while the patient is stabilised (push against an anatomic structure)
- Reverse anticoagulation
- Check Hb every 6 hours
- DUS to exclude pseudoaneurysm
- Open surgical repair
- Indications: haemodynamic instability, persistent anaemia despite transfusions, pseudoaneurysm unsuitable for thrombin injection; skin compromised, nerve compression, severe pain
- Retroperitoneal haematoma:
- Suspect in hypotension, diaphoresis, groin pain, abdominal pain, bradycardia, back pain
- CT is best test
- Indications for intervention - neurologic deficits in the extremity, haemodynamic instability, ongoing blood loss, severe pain
- Open procedure:
- Either groin incision or an incision above inguinal ligament
- Expose arteriotomy and repair
- Endovascular option would be a covered stent, good in high injuries
- Initial management:
- Thrombosis (2%)
- Risk factors - significant local atherosclerotic disease, previous groin reconstruction
- Usually becomes apparent after manual compression is complete
- Endovascular - mechanical thrombectomy, thrombolysis, atherectomy
- Surgical - groin exploration with femoral endarterectomy, patch angioplasty, thromboembolectomy
- AVF (0.9%)
- Tend to occur with more distal punctures, especially of PFA itself
- Detected by palpable thrill or continuous bruit
- Check for distal ischaemia and cardiac dysfunction
- DUS best test to diagnose
- Many are asymptomatic and will close spontaneously (38% within 12 months). Need follow-up DUS.
- Persistent, symptomatic or enlarging AVF should undergo repair
- Surgical: open cut-down
- Endovascular - balloon-expandable stent grafts
- Pseudoaneurysm (0.6%)
- Pulsatile groin mass, systolic bruit
- Perform DUS if suspicious
- If there is significant extension into the retroperitoneum, CT might help to fully define its extent
- Complications: nerve compression, distal embolisation, skin necrosis
- Observation alone is reasonable in small PSAs
- USS-guided compression works 74%-93%. Less effective on anticoagulation, large pseudoaneurysms, patient discomfort.
- Thrombin injection for pseudoaneurysm
- Allows fibrin clot to form and thrombose the PSA
- Indications: persistent, enlarging, symptomatic
- Needs to be a long pseudo aneurysm with a narrow neck (<0.55cm) to reduce the risk of injecting thrombin into the artery (very difficult to get out if that happens)
- Anticoagulation use associated with incomplete thrombosis
- Surgery:
- Larger PSAs
- Wide neck
- Failed alternative treatment
- Endovascular is a possibility
- Risk factors
- Catheter/guidewire related
- Perforation
- Confirm with extravasation of contrast
- Usually seals with conservative management
- Management depends on vessel and clinical status
- Can use covered stents
- Angioplasty-induced perforation of infra-inguinal vessels isn't life-threatening but can result in pseudoaneurysm or occlusion
- Dissection (7% after PTA)
- Balloon inflation causes stretching and disruption of the plaque and overlying intima that results in a tear or dissection. This can be propagated distally and result in flow-limiting obstruction or arterial occlusion.
- Seen on arteriography - luminal flap with contrast on both sides
- Usually treated by sustained inflation of low-pressure angioplasty balloon in an attempt to 'tack down' the dissection flap
- If unsuccessful (>30% or flow-limiting dissection), stent can be used
- Embolisation (1-3%)
- Any wire, catheter or sheath manipulation (especially atherectomy though) can result in embolisation, in patients with large-volume atheromatous disease
- Can result in trashing of runoff vessels, or stroke if in aortic arch
- Prevention better than cure - institute anticoagulation prior and minimise manipulation across the lesion, and can use embolic prevention devices in setting of large-volume plaque burden, significant thrombus burden or single-vessel runoff
- Management:
- Endovascular rescue - heparinise, trial with aspiration catheter, or trial with AngioJet if you think it's thrombus, thrombolytics
- If unsuccessful and there are signs of acute ischaemia, treat with standard open procedures
- Perforation
- Systemic
- HIT