Jump to content
Main menu
Main menu
move to sidebar
hide
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
Special pages
Surgopaedia
Search
Search
Appearance
Create account
Log in
Personal tools
Not logged in
Talk
Contributions
Create account
Log in
Editing
Angiogram
Page
Discussion
English
Read
Edit
Edit source
View history
Tools
Tools
move to sidebar
hide
Actions
Read
Edit
Edit source
View history
General
What links here
Related changes
Page information
Appearance
move to sidebar
hide
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
== Preparation == * Review imaging/previous angiograms * Hb and eGFR * Consent * Orientation of room * Level of sedation ** GA required for unco-operative patient, unable to lie flat, difficult to access artery == Therapeutic technique == * Balloon angioplasty ** Mechanism: blunt dehiscence leading to fracture and separation of the intima from the media, with stretching of media and adventitia ** Types of systems: *** Over-the-wire **** Wire passes through the entire catheter **** Good support, high pushabiity **** Allows for guidewire exchange when a lesion is difficult to cross *** Single-operator exchange aka monorail or rapid exchange **** Wire enters from the distal tip of the catheter and exits from a side-hole 20-25cm proximal to the balloon **** Used in coronary interventions and for below-knee lesions **** Easier to use because a single person can deliver and exchange it close to the insertion point ** Balloon characteristics *** Compliance - degree of expansile ability - function of pressure and diameter **** Compliant balloons are superior in trackability and suitable for lesions in a curved part of the vessel. Not suitable for severely calcific lesions as it may damage the adjacent normal vessel. **** Non-compliant balloons aka high-pressure or low compliance balloons. Allow for high-pressure expansion and have a higher RBP than compliant balloons. **** Nominal pressure - the pressure at which the balloon expands to its determined diameter and length, generally 3-10 atmospheres **** Rated burst pressure is the pressure at which <1% of tested balloons will burst, but beyond which the probability of rupture increases, typically 6-16 atmospheres **** Mean burst pressure - pressure at which 50% of balloons will rupture - usually 10-27 atmospheres *** Profile and balloon ability **** Profile - French size - smaller profile is better than a larger in terms of deliverability to the lesion and the ability to cross severely stenotic lesions **** Trackability - ability to follow guidewire without loss of wire position, which is important when following a tortuous vessel **** Pushability - ability to transmit force along the length of the balloon catheter to the target lesions. Better with larger balloons and OTW systems. **** Crossability - ability to cross stenotic lesions - depends on tip features and low-friction systems *** Types of balloons **** Cutting balloons - 3 or 4 artherotomes mounted longitudinally along the surface of a standard PTA balloon **** Cryoplasty - uses cooling and pressure to dilate the plaque and the vessel wall **** Focal pressure balloon **** Drug coated balloon ***** Adopts the technology from DES ***** Coated with anti-proliferative drugs such as paclitaxel ***** Favourable outcomes in terms of lumen size and long-term patency compared to standard balloons, but really long-term data are lacking ***** Perform pre-dilation with a standard balloon before using DCB ** Technique: *** Mostly done with 6Fr access *** Systemic heparinisation - 50-100U/kg prior *** Pass the wire through the lesion via the true lumen **** Use a 0.035 hydrophilic wire for most lesions **** 0.018 for highly stenotic lesions *** Balloon selection **** Balloons are available up to 30cm in length **** Mostly start off with an undersized balloon then work up to target size **** *** Balloon placement - re-DSA the lesion just prior to balloon placement *** Difficulty during balloon passage **** Exchange the wire for a stiffer wire **** Advance the sheath or guide catheter closer to the lesion **** Switch to a lower-profile balloon or one with greater pushability *** Balloon inflation **** Ensure it is flushed prior to insertion **** Replace the existing air inside the balloon with 25-50% contrast **** Most severe stenotic lesion should be in the middle of the balloon **** Monitor balloon shape in real time with fluoroscopy **** Typically keep inflated for 30-60 seconds **** Risk of rupture if patient complains of severe pain during expansion - maintain position across the lesion in case stenting is required *** Completion angiography ** Complications *** Dissection ''Grade A is a small radiolucent area within the lumen of the'' ''vessel disappearing with the passage of the contrast material.'' ''Grade B is a filling defect parallel to the lumen of the vessel'' ''disappearing with the passage of contrast material. Grade C is'' ''a dissection protruding inside the lumen of the vessel persisting'' ''after passage of contrast material. Grade D is a spiral-shaped'' ''filling defect with delayed run-off of the contrast material in'' ''the distal vessel. Grade E is a persistent luminal filling defect'' ''with delayed antegrade flow. Grade F is a filling defect accompanied'' ''by total occlusion. Stenting is typically required with'' ''Grade C to F dissections.'' * Stents ** Mechanism: useful in reducing the incidence of restenosis or address balloon PTA failure due to elastic recoil or dissection ** Mostly based on nitinol - an alloy of nickel and titanium ** Types: *** Balloon-expanding (BES) **** Balloon is inflated to deploy the stent **** Suitable only for vessels that are not prone to external compression (become irreversibly deformed) - avoid in ICA or SFA **** Can be placed more precisely than SES **** Tend to be more radio-opaque than SES **** Good for renal, mesenteric, iliac, subclavian, or brachiocephalic arteries *** Self-expanding **** Mostly nitinol **** More flexible - greater trackability, and resistant to fracture **** Less likely to cause interference on MRI **** Most stents are stored in the delivery sheath, and deployed from the distal end to the proximal end by unsheathing, and generally can't be repositioned after that **** Generally OTW systems **** Classified as open-cell (cylindrical structure of stacked serrated metal) or closed-cell (all edges and vertices of the stent cells are shared with an adjacent cell - preferable for lesions at risk of embolisation because the mesh is very fine) design *** Bare metal **** Mostly stainless steel/nitinol/cobalt chrome or other alloys *** Covered **** Can be PTFE, polyurethane, or silicon *** Stent grafts **** Balloon-expanding or self-expanding **** Stent struts with something like PTFE shell **** Can be used for perforations or for various occlusive lesions *** Drug-eluting stents ** Complications: *** In-stent restenosis *** Stent fractures == Atherectomy devices == * Ideally achieve patency without the need for stenting - especially useful for areas where stenting should be avoided (CFA, POPA behind knee) * Types: ** Direction *** Carbide cutting blade with a variable height and a plunger used to pack the atheroma into the nose cone *** Cutting blade rotates at up to 8000rpm *** Designed for treating severe calcification ** Rotational *** Insert a small drill into the artery to fracture a plaque and create a smooth lumen ** Laser atherectomy Thromboembolectomy * Aspiration ** Simplest way to remove thrombus - aspirate it with a large catheter or sheath (Export, PriorityOne, Pronto) ** Risk of distal embolisation remains - thrombolytic drugs often used in combination ** Work better in smaller vessels (<6mm) * Rheolytic ** Jet of saline ejected from the tip of the catheter and used to dissolve it * Rotational ** Remove the thrombus by rotating the tip of the catheter Intra-luminal devices to cross chronic total occlusions * Can be difficult or impossible to cross the plaque or segment of poorly organised thrombus, which often has a fibrotic or calcified cap at both ends, due to an inability to generate enough axial force through the guidewire * Devices such as Crosser, TruePath, Frontrunner XP can be used to assist Re-entry devices * Outback LTD Re-Entry System - penetrates the intimal flap, redirecting the guidewire from the subintimal plane to the true lumen * Other devices for similar effects Embolisation devices * Used to treat bleeding, small aneurysms, fistulas or endoleaks * Mechanical ** Coils ** Vascular plugs * Particulates ** Polyvinyl alcohol ** Gelatin microspheres * Liquid agents ** Absolute ethanol ** N-butyl cyanoacrylate == Vascular closure devices == * So far demonstrated to be non-inferior to manual compression * AngioSeal - sandwiches the arteriotomy with a bioabsorbable anchor connected with sutures and a collagen sponge that dissolve within 60-90 days. Compatimble with 5-8Fr sheaths. * Exoseal - bioabsorbable polyglycolic acid to achieve haemostasis. Compatible with 5-7Fr. * Mynx - polyethylene glycol sealant deployed outside the artery, while a small balloon inflates the arteriotomy site to create temporary haemostasis within the artery. 5-7Fr. * ProGlide - suture-based - mimics open surgical closure. 5-21Fr. * Prostar XL - for large bore device closures. [[Category:Vascular]]
Summary:
Please note that all contributions to Surgopaedia may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
Surgopaedia:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Search
Search
Editing
Angiogram
Add topic